  Datasheet File OCR Text:
 Current Transducer LA 25-NP/SP11
For the electronic measurement of currents : DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
1A
16095
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with 15 V ISN KN VC IC Vd Vb @ 1.0 A max @ 1.5 A max 1 0 .. 1.5 R M min R M max 100 100 320 190 A A mA V mA kV V V
Features
* Closed loop (compensated) multiturns current transducer using the Hall effect * Insulated plastic case recognized according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage ( 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. rated voltage 1), safe separation basic isolation
25 25 : 1000 15 10 + IS 2.5 600 1700
Special features
* IPN = 1 A * IP = 0 .. 1.5 A * K N = 25 : 1000.
Accuracy - Dynamic performance data
X
Advantages
0.5 < 0.2 Typ 0.05 0.05 0.06 0.10 Max 0.15 0.15 0.25 0.35 % % mA mA mA mA s kHz
L
Typical accuracy @ IPN , TA = 25C Linearity Offset current 2) @ IP = 0, TA = 25C Residual current 3) @ IP = 0, after an overload of 3 x IPN Thermal drift of IO 0C .. + 25C + 25C .. + 70C Response time 4) @ 90 % of IP max Frequency bandwidth (- 1 dB)
IO IOM IOT tr f
* * * * * * *
<1 DC .. 150
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference * Current overload capability.
Applications General data
TA TS RP RS LP R IS m Ambient operating temperature Ambient storage temperature Primary coil resistance @ TA = 25C Secondary coil resistance @ TA = 70C Primary insertion inductance Isolation resistance @ 500 V, TA = 25C Mass Standards
1) 2) 3) 4)
* AC variable speed drives and servo
0 .. + 70 C - 25 .. + 85 C < 51 m 110 31 H > 1500 M 22 g EN 50178 : 1997 motor drives
* Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies
(UPS)
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
applications.
Notes :
Pollution class 2 Measurement carried out after 15 mn functioning The result of the coercive field of the magnetic circuit With a di/dt of 100 A/s.
060405/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/2
LEM
w w w .lem.com
Dimensions LA 25-NP/SP11
Bottom view
(in mm. 1 mm = 0.0394 inch)
Right view
Top view
swiss made
Standard 00 or N SP..
Year
Week
Secondary terminals
Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V
Connection
in out
Back view Mechanical characteristics
* General tolerance * Fastening & connection of primary
0.2 mm 2 pins 0.635 x 0.635 mm * Fastening & connection of secondary 3 pins 1 mm * Recommended PCB hole 1.2 mm
Remark
* IS is positive when IP flows from terminal + to terminal -.
060405/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 2/2
LEM
w w w .lem.com


▲Up To Search▲   

 
Price & Availability of LA25-SP11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X